Ultimate-Pro Dual Stage CO2 Regulator Setup Instructions

Buy This Regulator Here

 

Know Your Regulator

Dual Stage CO2 Pro Regulator layout
A: 12v input cable (mains to 12v transformer is provided).
B: Needle valve adjuster; varies the CO2 dose. Turn anticlockwise to increase flow, clockwise to decrease flow.
C: Needle valve output.
D: Solenoid valve. Plug into a timer plug or pH controller to only dose CO2 at specified times and durations.
E: Working output pressure gauge.
F: Cylinder pressure gauge.
G: Pressure adjuster knob (clockwise increases pressure, anticlockwise decreases pressure).
H: Purge valve.
I: Nut: must be tightened using wrench / spanner.

Video


Step-by-Step

Tighten dual stage regulator to CO2 cylinder
Step 1) Tighten the regulator to your CO2 cylinder using a spanner or wrench. Do not hold the regulator while tightening; allow it to freely rotate. If you hold the regulator while tightening the nut, then the friction between the nut and the stem can cause the stem to turn anticlockwise and unscrew from the main body of the regulator, which will result in a leak.
Set output pressure of dual stage regulator
Step 2) Set the output pressure to minimum by turning the pressure adjuster knob fully anticlockwise.
Close needle valve flow controller
Step 3) Close the needle valve by turning fully clockwise.
Switch CO2 solenoid on
Step 4) Plug the solenoid into a mains socket and switch on.
Open flow of gas from CO2 cylinder
Step 5) Open the flow of gas from your CO2 cylinder.
Pressure gauge showing cylinder pressure
Step 6) The cylinder presure gauge will now indicate the pressure of the cylinder.
Pressure gauge showing cylinder pressure
Step 7) Turn the pressure adjuster knob clockwise to increase output pressure. As a starting point set to 40PSI / 3 Bar.
Adjust bubble rate using needle valve
Step 8) Your regulator is now ready for use.
Adjust bubble rate using needle valve
Step 9) With the bubble counter and diffuser installed, turn the needle valve anticlockwise to allow gas to flow out of the regulator and to the diffuser via the bubble counter. Once you see bubbles coming from the diffuser it indicates the system is fully pressurised and you can then set your desired bubble rate by adjusting the needle valve.

As a rough guide, 1 bubble per second is suitable for a 150L aquarium - adjust your dosing in accordance to this, i.e. 2 bubbles per second for 300L aquarium.


Check for Leaks

It is recommend that each time you reconnect the regulator to the CO2 supply that you check for leaks. Identifying a leak from the outset is a much more desirable result than discovering there is a leak only when a substantial amount (or all) of your CO2 cylinder has leaked.

The easiest way to check for leaks is to cover all of the joins with soap suds, and look for any sign of bubbling, and also listen for a 'hissing' sound. If your regulator has a solenoid it is recommended that you switch off the electricity supply prior to applying soap suds. Please also try to only use the soap suds themselves, and as little water as possible.

Disconnecting from the CO2 Cylinder

If you wish to disconnect the regulator from the gas cylinder it is important you first purge the gas within the regulator. To do this, close the valve on the gas cylinder and then open the needle valve on the regulator to use the residual gas or pull the purge valve marked H on the first photo. Once the pressure gauges on the regulator show zero pressure it is safe to disconnect the regulator from the cylinder.